Commissioning Guide for the Fire Safety Stick Pro
A basic installation and commissioning guide for the Fire Safety Stick Pro*
*Fire Safety Stick Pro is the model designated for commercial (non-domestic) installations – it is comprised of the standard Fire Safety Stick FSS50 or FSS100 with an additional combination of the items listed below for commercial installations. Please note if you are looking to replace traditional fire extinguishers in a commercial premises there are requirements that must be followed including a refreshed independent fire risk assessment and an updated fire safety strategy.
The Fire Safety Stick is suitable for commercial vehicles. However, if the vehicle is governed by PSV (Public Service Vehicles) and ADR (Transport of Dangerous Goods by Road) regulations, then you will still need to carry the specified traditional extinguisher but can also carry the Fire Safety Stick in addition, with the benefit of its key advantages.
Click here – To see some demonstrations carried out for clients who have since added the Fire Safety Stick to their fire safety solutions.:
For Domestic installations, please click here
For commercial installations such as in buildings or vehicles, the following is a guide to the necessary items which are recommended as part of the commissioning of the Fire Safety Stick Pro
Items needed for a full commercial installation of the Fire Safety Stick Pro:
- Standard FSS50 or FSS100 model (Or a Utility pack version comprising of extra mounting clip and tamper tag fitted)
- Tamper Tag – fitted to the handle and bottom striker cap.
- Installation Date Sticker – to be applied to the black plastic handle.
- Maintenance Sticker – to be applied to the tamper tag.
- Fire Safety Stick Wall sign – Identifying the model, the classes of fire certified for and basic instructions. These are available as rigid photoluminescent sign typically for installations within buildings, or as a vinyl sticker with permanent adhesive, typically used for installations within commercial vehicles.
- Fire Safety Stick Inspection Record sheet – this can be downloaded as A4 pdf here and provides the appropriate documentation (where required) of the regular maintenance inspections of the Fire Safety Stick. Remember, this can be carried out by the responsible persons for the business and does not necessarily need to be carried out by external fire safety technicians.
Secure wall installation with sign
Photo-luminescent sign
Maintenance record sheet (or fire safety logbook)
FSS with tamper-tag securing the base striker cap
Commissioning
Typically, your Fire Safety Stick Pro supplier would have supplied the sticks with the tamper tag, installation and maintenance stickers already fitted to the FSS, providing it was specified. If the items were supplied separately, not fitted, then please apply the stickers as shown in the image. For instructions on fitting the Tamper Tag, please follow this video link.
Mounting the Fire Safety Stick Pro
Fix the mounting clips to the surface, recommended with mounting screws (not supplied), or suitable adhesive. Please note the Fire Safety Stick is not restricted at all with regards to the positioning/orientation of placement.
Wall Signage
The sign should be installed just by the installed Fire Safety Stick. In the case of the rigid photoluminescent sign, it will need some form of adhesive (or mounting pads) to hold it in place. For the vinyl wall sticker, simply peel off the backing paper and apply it to the surface. Then, for either version, with a permanent marker pen, tick the box on the sign for the corresponding model, along with the location ID (optional).
Installation Sticker (Applied to the handle)
Once installed, record the date on the installation sticker placed on the handle and sign it.
FSS Inspection Record Sheet
Record the date of installation, as well as location, FSS Model and ID number (if used) on the FSS Inspection (or maintenance) Record sheet. We would recommend that the sheets used for the commercial installation are then secured to the main Fire Safety Logbook for the premises.
If you have any queries on the process of installation and commissioning of the Fire Safety Stick Pro, please contact the Fire Safety Stick head office on +44 (0)1582 879529.
The Difference between Servicing and Maintenance for Fire Extinguishers
The Fire Safety Stick needs no servicing during its life-cycle of 15 years, it just needs to be visually inspected or maintained and logged by the building owner or responsible person. Traditional fire extinguishers need to serviced at least every year. This is to check the pressure within the container, simply checking the gauge is not sufficient. O-rings need to be replaced, pipes and weights professionally checked. It should also be noted that at end of life, traditional extinguishers cannot be just disposed of, but because they are pressurised systems, they must be professionally recycled.
Of course, if you prefer, you can have your existing fire or security company carry out the maintenance checks and log them in your on-site fire safety logbook, whilst they are on site. The Fire Safety Stick is not pressurised and once discharged, can be easily domestically recycled as all that remains is an aluminium tube and a plastic handle. The solid resin inside it does not decompose at all and again needs no servicing at all.
About the FSS team
The senior management of the Fire Safety Stick team, prior to introducing this unique extinguisher to the UK market, owned and managed one of the UK’s leading Fire Safety companies. Specialising in Fire alarms, extinguishers and other life safety solutions such as smoke ventilation systems in commercial and residential properties, the company had the highest possible accreditations available in fire safety and smoke ventilation. In 2020, Sergio De Michele, sold the business to concentrate purely on the Fire Safety Stick and bring it to all possible sectors including the home and commercial sectors.
Domestic Installations of the Fire Safety Stick
For most domestic installations the standard Fire Safety Stick can be installed with its free supplied mounting clip, with no additional requirements. However, depending on the environment being situated, such as off-road vehicles for example, the user may wish to combine some of the following additional measures. These could include an extra mounting clip to secure the FSS with two clips, or a specialist bracket also available from Fire Safety Stick. Also, you may wish to further secure the bottom striker cap with a fitted tag, the details of which are shown below.
For further installation advice for consumers, please see this page: Domestic Installations Info